Temperature range |
+ 20 ºC - 300 ºC |
Temperature rise speed |
Rise from room temperature to 300 ºC for about 35 minutes |
Insulation performance |
The outer wall temperature shall not exceed 45 ºC (when the furnace temperature reaches 200 ºC) |
Temperature control accuracy |
± 1 ºC |
Temperature uniformity |
± 3 ºC |
Power supply |
380V / 50Hz |
Equipment construction: |
Color |
Overall spraying of Matt amino paint, silver grey |
Equipment positioning |
Iron foot support at the bottom, and the height from the lower plane of the liner to the ground is 380mm |
Inner chamber size |
1300mm * 1520mm * 710mm |
Material placement |
Equipped with two movable drying racks, each with 8 trays |
Heat source configuration |
3 W-type heat pipes with metal sheath, in the top air duct |
Circulation mode |
Horizontal air supply, 1 set of 370W motor |
Air intake and exhaust |
Air intake from fan shaft hole. Top vent, manual vent |
Sheet metal structure |
1mm stainless steel plate for inner tank, 1mm cold-rolled plate for outer shell, bending, splicing and welding |
Framework structure |
The whole 4-angle steel frame, the bottom 5-angle steel frame, the door frame 5mm thick sheet metal reinforcement |
Insulation layer |
90mm aluminum silicate fiber |
Structure |
single door, silicone strip seal, alloy hinge, rocker lock |
Electrical control: |
Dual digital PID intelligent temperature controller main control |
Independent temperature measurement by the monitor, over temperature protection circuit to monitor the overall operation of the equipment to ensure the safety of the equipment and drying materials |
Adopt SSR solid-state relay to turn on and off to control the temperature rise of electric heater |
Equipped with 0-99.99 hour timer, which can be used for direct timing or temperature timing, and automatically cut off heating and alarm when the time is up |
Air blast heating interlock protection circuit, that is, air blast before heating to prevent heater from dry burning |
The phase sequence protector shall prevent the reverse operation of the fan caused by the reverse connection or lack of phase sequence |
Heating circuit breaker to prevent accidents caused by overload and short circuit of heating circuit |
Fan and control circuit breaker shall prevent overload and short circuit of fan and control circuit from causing accidents |
The temperature recorder records the temperature curve of the working area in real time, which is used to analyze the material baking process (optional) |