• TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing
  • TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing
  • TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing
  • TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing
  • TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing
  • TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing

TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing

Warranty: 1 year
Type: Lithium Battery
Test Region: Charge and Discharge
Application: Lithium-ion Battery
Customized: Customized
Communication mode: RJ45(Network port)
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
TMAX-BTS-60V40A
Current stability
less than 0.05%
Transport Package
Wood Packing
Trademark
TMAX
Origin
China

Product Description

 
TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing
60V40A 1 Channel Battery Tester for the Power Battery/Prismatic Battery/ Battery Pack Testing
 

System Features
1.Single point independent, independent charging and discharging steps can be set for each battery test channel.
2.The accuracy of the equipment is 0.05%, the data recording time is 1 s / time, the fastest is 0.1 s / time, and the stability is high.
3.The software has powerful function and friendly man-machine interface.
4.Four wire test interface ensures high measurement accuracy.
5.Modular design concept, easy to maintain.


Equipment Description
TMAX high precision battery test system is mainly designed for power battery / battery pack, which can meet  the performance test requirements of power battery pack. The equipment has the characteristics of high power, high precision and high performance. It can charge the equipment voltage from 0 to 60 V and discharge from 60V to 5V, and charge and discharge test and capacity division of batteries with various specifications from 0 to 40A.


Device View
View size of single table (external dimension: length * width * height = 800 * 650 * 178mm)
TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing



 View dimension of the whole cabinet (external dimension: L * w * H = 790*950*1806mm)

TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing


Product Specification
Equipment model UPC60V40A-01NC
Number of output channels of equipment model 1CH (1 channel per device)
Communication mode RJ45(Network port)
Charging voltage DC 0 ~ 60V charging can be used to detect and set the voltage range, the maximum voltage is 60V
Discharge voltage DC 60 ~ 5V discharge can be used to detect and set the voltage range, the maximum voltage is 60V
Charging current DC 0.02~ 40A can be used to detect and set the current range, the maximum current is 40A
Discharge current DC 0.02~ 40A can be used to detect and set the current range, the maximum current is 40A
Voltage accuracy ±(0.05%RD + 0.05%FS)
Current accuracy ±(0.05%RD + 0.05%FS)
Voltage resolution 1mV The minimum unit used by a device to detect or set voltage
Voltage stability ≤0.05%
Current resolution 1mA The minimum unit used by a device to detect or set current
Current stability ≤0.05%
Power output range 0.5~Pmax = Vmax * Imax
Input impedance >=10 MΩ
Input power AC 220 V ± 10% / 50 Hz (cabinet power supply mode: three phase five wire)
Power accuracy ±(0.05%RD + 0.05%FS)
Current response time When the current output is 40A, the hardware response time is as follows:≤50ms
Time setting range Any setting within 0-9999 minutes, the time units are h, min and s, and the resolution is 0.1s
Time accuracy ≤±0.1%
Recording method Charging recording time, discharging recording time, static recording time and global recording time
Recording frequency 100mS~65535S
Sampling frequency About 10ms per box
Charging mode Constant current and voltage limiting, constant current and constant voltage, constant power charging, constant flow charging test (battery with protection board)
Charging cut-off conditions Voltage, current, time, capacity, temperature
Discharge mode Constant current and constant power discharge (battery with protection board)
Discharge cut-off conditions Voltage, current, time, capacity, temperature
Protection function Data abnormal recovery; battery reverse connection protection function;
Software over-voltage, under voltage, over-current, under current and over capacity protection. The range of voltage and current protection value can be set, and prompt and record after protection;
Number of single cycle work steps ≤100 steps, with nested loop function
Continuous working hours The power of the equipment shall meet the requirements of full load and 365 * 24-hour uninterrupted operation of all channels
Equipment noise Less than 60dB
Circuit structure Modular structure design, easy to replace and maintain
VCELL,TCELL Auxiliary temperature and voltage can be selected and 16 channels in single box can be selected
 
 
 
 
 
 
 
Software
The software supports various kinds of connection, such as manual suspension connection, software shutdown connection, power interruption connection, equipment communication interruption connection and abnormal stop connection;
It supports barcode scanning, and can scan one-dimensional code and two-dimensional code. There are scanning methods such as sequential scanning, channel skipping scanning, loading and disk scanning;
Local test detailed data storage, you can view the current test data and historical data of each channel at any time. There are two ways to display the corresponding data and curve. It also supports the export of excel report in single or batch form. In addition, it can set the automatic data export after the test according to the needs.
It supports capacity sorting and can grade sort the battery;
The pass / ng results can be judged according to the specified cycle capacity, voltage and time;
Support all kinds of work step protection and global voltage, current and temperature abnormal protection, and carry out abnormal alarm, support battery pack overcharge and over discharge protection test;
Support channel parallel connection (optional according to equipment);
Support unit conversion;
Support database server background storage or MES docking;
Software offline protection;
The software provides free upgrades.
Operating / storage temperature 0ºC~40ºC/-10ºC~50ºC
Relative humidity of working / storage environment ≤70% RH / ≤ 80% RH (no condensation)
Equipment maintenance Non professionals are not allowed to open the case. Check the equipment joint regularly to prevent poor contact.
 
TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing

           
TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing

TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing
TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing
TMAXCN Brand 60V40A Battery Tester for Primatic Cell Or Battery Pack Testing

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now