Customization: | Available |
---|---|
Production Scope: | Product Line |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Project Index | Parameter Index | |
Input AC Power | AC 380V ±10% / 50Hz | |
Input Impedance | ≥100KΩ | |
Input Power | 14177W | |
Resolution | AD:16bit;DA:16bit | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Each Channel Voltage Range | 0.025mV~5V |
Ll | Lowest Discharge Voltage | 2V |
Accuracy | ± 0.1% of FS | |
Stability | ± 0.1% of FS | |
Current | Each Channel Current Range | Range :0.5A~100A |
Cut Off Current | 0.2A | |
Accuracy | ± 0.1% of FS | |
Stability | ± 0.1% of FS | |
Power | Each Channel Max. Output Power | 500W |
Stability | 0.2% of FS | |
Time | Current Rise Time | The current gets to (10%-90%) hardware rise time is 20ms |
Step Time Range | 1s≤Single Step Time Range≤365*24 h, Support Time Form: 00:00:00:00(h,min,s,ms) |
|
Data Recording | Record Condition | Min. Record Time:100ms |
Min. Record Voltage:10mV | ||
Min. Record Current:200mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | Constant Current Charge,Constant Voltage Charge,Constant Power Charge,Constant Current and Constant Voltage Charge |
End Condition | Voltage,Current,Relative Time,Capacity,Relative Voltage | |
Discharge | Discharge Mode | Constant Current Discharge,Constant Power Discharge,Constant Resistance Discharge |
End Condition | Current,Voltage,Relative Time,Capacity,Relative Voltage | |
Cycle | Loop Measure Range | 1~65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function,Max Support 3 Layers | |
Pulse Model | Charge | Constant Current,Constant Power |
Discharge | Constant Current,Constant Power | |
Min Pulse Width | 200ms | |
Pulse Number | Single Pulse Step Support 32 different Pulse | |
Charge r To Discharge | One Pulse Step Can Support Continuous Charge And Discharge Change | |
Stop Condition | Voltage, Relative Time | |
DCIR Testing | Support Custom Access Point And Count The DCR | |
Channel Parallel | Support Channel Parallel(4 channels max),Under Parallel Without Pulse Function | |
Protective Function | Software Protection | l Power-down Data Protection |
l Off-line Testing Function | ||
l Setting Protection Condition,Setting Parameter:Low Voltage Limit,Upper Voltage Limit,Low Current Limit,Upper Current Limit,Delay Time | ||
Hardware Protection | Additional Anti-reverse Protection Model | |
Data Output | EXCEL,TXT | |
Communication Interface | Ethernet Port | |
No. Of Channels Per Unit | 16 | |
Dimensions (W*D*H) | 600*600*1780(mm) |