Customization: | Available |
---|---|
Production Scope: | Product Line |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Channel | 192 |
Constant current range | 0.1~10000mA,resolution 10mA |
Current accuracy measurement | ±(0.1%RD+0.1%FS) |
Sampling inspection interval | ≤2 s/cycle |
Voltage measurement range | 0~5V,resolution 1mV |
Voltage measurement accuracy | ±(0.1%RD+0.1%FS) |
Voltage range of tested battery | 2~4.5V |
Constant voltage setting range | 3 ~4.5V |
Accuracy of constant pressure setting | ±(0.1%RD+0.1%FS) |
Time range | 0~30000 minute/stepp,accuracy:±0.1% |
Support battery height | 20~150mm,Stepless regulation |
Fixture form | Tray + polymer, tray + alligator clip, cylinder four wire method |
Size | 1430mm(W)×600mm(L)×1840mm(H) |
Working power supply | Three phase four wire system, AC380V ± 10%, 50Hz |
Full load power consumption | ≤14KW |