Model No. and structure:
Model No.:TMAX-EF128-30k;
Equipment structure: The fixture adopts an overall automatic downward pressure design, and the batteries are placed on both sides
Machine size reference(mm):L2130mm*W700mm*H2020mm
Note: The positive and negative fixtures are designed using a pneumatic overall pressing method, with a maximum compatible distance of 150mm and a minimum distance of 45mm between the positive and negative electrode. The maximum height of compatible batteries is 220mm.
Item | Specification |
Fixture type | True four wire method multi needle clamp with adjustable spacing between positive and negative electrodes. |
Tray height spacing | 270MM |
Minimum floor height above ground | 270MM |
The highest level above the ground | 1620MM |
Center distance between fixtures | 78.5MM |
Compatible battery height | 50-220MM |
ITEM | TMAX-EF128-30K |
Channel | 128 channel |
Charging/discharging current range(mA) | 200~30000 |
Current measurement accuracy | ±0.05%FS+0.05%RD |
Current resolution(mA) | 1 |
Voltage measurement range(mV) | 0~5000 |
Charging voltage range(mV) | 0~4500 |
Discharge voltage range(mV) | 1800~4500 |
Voltage measurement accuracy | ±0.05%FS+0.05%RD |
Voltage resolution(mV) | 0.1 |
Time measurement range and accuracy | 999min/step,accuracy:±0.1% |
Equipment calibration method | Software digital calibration |
Calibration cycle | 6 months |
Work step content | Constant current charging, constant current constant voltage charging, constant current discharge, quiescent state |
Work step end conditions | Current, voltage, time, capacity |
Maximum number of steps set | 32 |
Maximum cycle set number | 256 |
Curve display | Charge discharge current curve, charge discharge voltage curve, capacity curve |
Capacity sharing method | Capacity grading, time grading, capacity+curve grading, time+curve grading, capacity+voltage grading, fixed point voltage grading |
Protection method | Over current, under current, over voltage, under voltage, over capacity, and leakage current, with dual protection of hardware and software for charging over voltage/discharging under voltage |
data statistics | The open circuit voltage, average voltage, working time, current, capacity, and platform capacity of each battery at each step; Detailed curves and data for each step; Count the number of batteries in each capacity segment, etc |
Inspection speed(s) | ≤6 |
Communication method | RS485/WIFI |
Battery scanning function | Support barcode scanning, capable of scanning one-dimensional and two-dimensional codes, including sequential scanning and channel skip scanning, and binding with device channel information for easy traceability in the future. (According to the barcode method of the user, the wireless scanning gun is provided by Party B) |
Data processing function | 1. Local data Save detailed data of the device's operation locally, without deleting it. Follow the process of saving one file per run, and the data file can be copied to other computers for viewing. Save the result data of the device's work locally, without deleting it. Save a CSV file for each process run, and only save the end data of each step in the result data file. 2. Server data If a data server is configured, the result data can be uploaded to the number of servers According to the database, the retention period can be set according to customer requirements, and this CSV file is the standard Database format, which can be integrated with the MES system |
Number of controllable devices per computer | 1~10 |
Frame size (mm) (reference) | L2130mm*W700mm*H2020mm |
Total power of equipment(KW) | ≤34 |
Power efficiency | The charging and discharging power supply adopts energy-saving power supply, and the battery discharge energy is fed back to the power grid. The maximum efficiency of power charging output shall not be less than 70%, and the maximum efficiency of power recycling shall not be less than 65%. |
Equipment stability | The equipment has good long-term stability and accuracy calibration ensures that it does not exceed the agreed accuracy control range within 6 months. |
Working power supply | 3 phase,AC380V±10% 50Hz |
Air switch | Three phase four wire air switch with zero line leakage protection function |
Working compressed air | Not less than0.5MPa/air inlet:10mm |