Customization: | Available |
---|---|
Production Scope: | Product Line |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Neware Lab 5V 20A 8 Channel Testing Machine Battery Charge And Discharge Tester
BTS-5V20A Battery testing equipment | |||
Equipment model: BTS-5V20A | Battery testing equipment | Equipment material code: CT-4008 -5V20A | |
Index items | Index parameters | ||
Input power | AC 220V ±10% / 50Hz | ||
Input active power | 1418 W | ||
Resolving power | AD:16bit;DA:16bit | ||
Input impedance | ≥1MΩ | ||
Voltage |
Constant voltage range control | 0.025V~5V | |
Minimum discharge voltage | 2V | ||
Accuracy | ± 0.1% of FS | ||
Stability | ± 0.1% of FS | ||
Current |
Output range per channel | 0.1A~20A | |
Accuracy | ± 0.1% of FS | ||
Constant voltage cut-off current | 0.04A | ||
Stability | ± 0.1% of FS | ||
Power | Single channel maximum output power | 100 W | |
Stability | ± 0.2% of FS | ||
Time | Current response time | Maximum current rise time 20ms | |
Step time range | ≤(365*24)hour; time format support00:00:00.000(h,min,s,ms) | ||
Data record |
Data recording conditions |
Minimum time interval:100ms | |
Minimum voltage interval:10mV | |||
Minimum current interval:40mA | |||
Recording frequency | 10Hz | ||
Charge |
Charging mode | Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging | |
Cut off conditions | Voltage, current, relative time, capacity, - △ V | ||
Discharge |
Discharge mode | Constant current discharge, constant power discharge, constant resistance discharge, support custom constant voltage discharge and constant current constant voltage discharge | |
Cut off conditions | Voltage, current, relative time, capacity | ||
Pulse mode |
Charge | Constant current mode, constant power mode | |
Discharge | Constant current mode, constant power mode | ||
Minimum pulse width | 500ms | ||
Number of pulses | A single pulse step supports 32 different pulses | ||
Charge discharge continuous switching | A pulse step can realize continuous switching from charging to discharging | ||
Cut off conditions | Voltage, relative time | ||
DCR test | Support user defined point for DCR calculation | ||
Loop |
Cycle test range | 1~65535times | |
Single cycle steps | 254 | ||
Loop nesting | It has nested loop function, and supports up to 3 layers of nesting |
Protect |
Power down data protection | |
With offline test function | ||
The safety protection conditions can be set, and the setting parameters include: upper voltage limit, lower voltage limit, upper current limit, lower current limit, upper capacity limit and delay time | ||
With anti reverse connection function (to be used with software) | ||
IP protection level | Protection grade IP20 | |
Channel characteristics | Constant current source and constant voltage source adopt double closed loop structure | |
Channel control mode | Independent control | |
Sampling of voltage and current detection | Four wire connection | |
Noise | <75dB | |
Database | Centralized management of test data with MySQL database | |
Communication mode of upper computer | Based on TCP / IP protocol | |
Data output mode | EXCEL2003,2010,TXT | |
Server disk configuration | 500GB | |
Leakage current | 0.005mA | |
Server operating system | Windows 7,Windows 10 | |
Communication interface | Network port | |
Equipment working environment requirements | ||
Index items | Index parameters | |
Operating temperature range | 0ºC~40ºC(Within the range of 25 ± 10 ºC, the measurement accuracy is guaranteed: the accuracy drift is 0.005% of FS / ºC) | |
Storage temperature range | -10ºC~50ºC | |
Relative humidity range of working environment | ≤70% RH(There is no condensation) | |
Relative humidity range of storage environment | ≤80% RH(There is no condensation) |