Customization: | Available |
---|---|
Warranty: | 1 Year |
Test Region: | Battery Short Circuit Test |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Control system | 1. PLC touch interface. 2. PID temperature control, automatic constant temperature and high temperature compensation. 3. Record battery surface temperature, current, and voltage. 4. The test process is automatically controlled. |
High current contactor |
1. The rated working current is 1000A DC, equipped with a series magnetic blowervertical partition clay extinguishing arc extinguishing system. 2. The electromagnetic system and the main contact arc extinguishing system are respectively fixed on the installation base frame, adopting a corner-turning beat-type electromagnetic system and a double-winding attraction coil to install a pressure ribbed device on the rotating edges and corners; 3. The contactor is made of copper. low resistance and fast response |
Remote control | 1. Long-distance wireless control; 2. Reliable, stable, self-locking and interlocking function, strong anti-interference ability, long service life |
Voltage acquisition | Measuring voltage: 0-100V, Guarantee test accuracy Display accuracy: F.S ±0.2% rdg ±1digit Action method: 2 integral methods Acquisition frequency: 2 times / second Number of channels: 2 channels |
Current acquisition | Measuring current: 0-1000A Display accuracy: F.S ±0.2% rdg ±1digit Action method: 2 integral methods Acquisition frequency: 2 times / second Number of channels: 2 channels |
Temperature acquisition | Measuring temperature: -20-600°C Display accuracy: 0.5°C Acquisition frequency: 1 time/second Number of channels: 4 channels |
Equipment material | Inner box 1.5mm SUS#201 stainless steel, Outer box: 1.5mm cold-rolled steel plate baking treatment |
Ventilation function | There is an air inlet on the left side of the equipment and a smoke outlet on the top. The exhaust gas produced during the test can be discharged to the outdoor through the top blower and reserved exhaust duct. |
Explosion-proof function | 1. The observation window is three layers of tempered glass. 2. Test box structure is divided into inner layer, outer layer, and intermediatesandwich. 3. The test box door is made of stainless steel high-strength hinge, safe and reliable. 4.Pressure relief device: there is a pressure relief and explosion-proof window at the back of the device, with a diameter of 100mm. |
Working voltage | Exchange 220V 50Hz-60Hz; |
Impact voltage | AC 1kv/1.2-50μs <peak value> 1min |
Operation characteristics | Cold state pull-in voltage ≯66%Us Cold state releasing voltage ≯30%Us,≮5%Us |
Short circuit mode | Pneumatic suction |
Maximum measurable battery voltage |
100V |
HVDC response time | ≤5μs |
Max. circuit current | 1000A |
Internal resistance of device | 80±20mΩ |
Remote control distance | 7 meter |
Test temperature range | RT+10~100ºC |
Current,voltage,temperature acquisition channels | Total 8 channels |
Actuation time | Response time / releasing time ≯30ms |
Mechanical life | 300,000 times |
Temperature control accuracy | 0.1ºC |
Temperature uniformity | ±2ºC |
Temperature fluctuation | ±0.5ºC |
Interior test chamber size | 400*400*400mm |
External test chamber size | 950*850*1650mm |
Working environment | Temperature: -10ºC~100ºC humidity: 10~90% |
Supply power | AC220V , 50HZ |
Equipment power | 2.5KW |