Customization: | Available |
---|---|
Production Scope: | Product Line |
Automation: | Automation |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Number of Device Channels | The whole machine has 256/ 512 channels in total |
Workflow Control Mode | Whole cabinet control |
Charging Mode | Constant current and constant voltage |
Charging Cut-off Conditions | Voltage, current, time, capacity |
Discharge Mode | Constant current |
Discharge Cut-off Conditions | Voltage, time and capacity |
Sampling Inspection Cycle | ≤10s |
Voltage Measurement Range | 0 ~ 5V, Resolution 1mV |
Battery Voltage Range | Charging: 0 ~ 4.5V, Discharging: 4.5 ~ 2V |
Constant Voltage Range | 3~4.5V |
Voltage Accuracy | ±(0.05%RD+0.1%FS) |
Current Range | Charge 0.025-6A, Discharge 0.025-6A, Resolution 1mA |
Current Accuracy | ±(0.1%RD+0.1%FS) |
Time Frame | Any setting within 0 ~ 30000 minutes, time unit is min |
Time Accuracy | ≤±0.1% |
Fixture Type | Cylindrical four wire fixture |
Fixture Spacing | 35mm |
Support Battery Height | 0~90mm |
Working Power Supply | Three phase four wire system, AC380V ± 5%, 50Hz, power consumption ≤14KW for 256 channel and ≤28KW for 512 channel |
Communication Mode | RS485, baud rate 57600 |
Overall Dimension | 720mm(Width)*500mm(Deep)*1840mm(High)for 256 channel 1440mm(Width)*500mm(Deep)*1840mm(High) for 512 channel |
Work Environment | Temperature: 0-40 ºC, relative temperature ≤ 85% |
Full Load Operating Current | he maximum phase line is 30A, and the maximum zero line is 3A |
Equipment Starting Current | The closing moment of air switch is about 60A |
Machine weight | About 100kg for 256 channel/ 250 kg for 512 channel |
5. Cabinet structure and opening mode
6. Equipment Reliability Assurance Measures
6.1 The machine adopts automatic calibration function to ensure that the current and voltage at each point meet the requirements of technical indicators for a long time. After the automatic calibration function is adopted, the potentiometer is cancelled on the circuit board, and the problem of current and voltage deviation caused by potentiometer drift is eliminated.
6.2 Low temperature drift alloy resistance is used for current sampling and it is sorted by high precision resistance value. High precision and high stability imported chip elements are used for voltage and current detection chip, which can effectively reduce temperature drift and time drift and ensure long-term stability and precision requirements of current.
6.3 All power devices are imported, and the margin of power device voltage and current quota selection is large, generally more than 2 times, which effectively ensures the reliability of the main circuit of each link hardware.