1. This tester can analyze polymer and cylindrical batteries from 0.1mA to 6 A, up to 5V.
2. The battery test system provides most applications in battery testing fields such as electrode materials research, battery performance test, small-scale battery formation, capability grading, battery pack testing and etc.
Project index |
Parameter index |
|
Input Power |
AC 220V ±10% / 50Hz |
|
resolution |
AD:16bit;DA:16bit |
|
Input Resistance |
≥1MΩ |
|
Input Power |
425W |
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Per Channel Voltage Range |
Charge:25mV~5V;Discharge:1.0V~5V |
Accuracy |
± 0.05% of FS |
|
Stability |
0.05% of FS |
|
Current |
Per Channel Output Current Range |
Range1:0.5mA~0.1A;Range2:0.1A~6A;Range3: 3A-6A |
Accuracy |
± 0.05% of FS |
|
CV cut-off current |
Range 1: 0.2mA Range2: 6mA; Range3: 12mA; |
|
Stability |
0.05% of FS |
|
Power |
Per Channel Output Power |
30W |
Stability |
± 0.1% of FS |
|
Time |
Current Response Time |
The Current gets to 6A Hardware Response Time is 1ms |
Step Time Range |
0.1s≤Single Step Time Range≤365*24 h, Time Form Support 00:00:00(h,min,s) |
|
Data Recording |
Record Condition |
Minimum Time interval:100ms |
Minimum Voltage interval:10mV |
||
Minimum Current interval:Range 1: 0.2mA Range2: 12mA |
||
Record Frequency |
10Hz |
|
Charge |
Charge Mode |
Constant Current Charge,Constant Voltage Charge, CC-CV Charge ,CP-Charge |
End Condition |
Voltage,Current,Relative Time,Capacity,Minimum Voltage interval |
|
Discharge |
Discharge Mode |
Constant Current Discharge CP-D CR-D |
End Condition |
Current,Current,Relative Time,Capacity,Minimum Voltage interval |
|
Pulse Model |
Charge |
Constant Current,Constant Power |
Discharge |
Constant Current,Constant Power |
|
Min Pulse Width |
500ms |
|
Pulse Number |
Single Pulse Step Support 32 different Pulse |
|
Charge r To Discharge |
One Pulse Step Can Support Continuous Charge And Discharge Change |
|
Stop Condition |
Voltage, Relative Time |
|
DCIR Testing |
Support Custom Access Point And Count The DCR |
|
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function,Max Support 3 Layers |
|
Protection |
Software Protection |
l Power-down Data Protection |
l Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time |
||
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
<85dB |
|
Data Management |
MySQL Database |
|
Communication Means |
TCP/IP Protocol |
|
Data Output |
EXCEL,TXT |
|
Communication Interface |
Ethernet Port |
|
Main Channels |
8 |
|
Dimensions |
3U,W*D*H:480*730*130(mm)per unit |
|
the total rack is 760*660*1960mm . The gross weight is 180KG |
||
Additional Function
|
Test: Temperature; voltage |
|
Temperature range: minus 25C-110C( Thermistor) |
||
Temperature accuracy:± 1C |
||
Temperature resolution:0.1C |
||
Voltage range:-5V-5V |
||
Voltage accuracy:± 0.1% of FS |
||
Can set the parameter: Upper and lower limit of voltage; Upper and lower limit of temperature ;single cell voltage difference |
Equipment Working Environment
Project index |
Parameter index |
Working Temperature Range |
0ºC~40ºC |
Storage Temperature Range |
-10ºC~45ºC |
Working Environment Relative Humidity Range |
30% ~ 80% RH |
Storage Environment Relative Humidity Range |
30% ~ 90% RH |