Customization: | Available |
---|---|
Production Scope: | Product Line |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
100V 20A Charge Discharge Regenerative Type Battery Pack Aging Machine
NO | Item | Function |
1 |
Charging |
1. Constant current charging, channel output with constant current, current output with soft start, no current impact; 2. Continuous mode constant current and constant voltage charging, while limiting voltage output and current output, automatic hardware switching, current hardware soft start, constant flow and constant voltage without impact current. |
2 | Discharging | 1. Constant current discharge, channel discharge with constant current, current control adopts soft start, no current impact; Constant power discharge. The channel discharges in a constant power discharge mode. The channel adjusts the current in real time according to the battery port voltage. |
3 | Standing | The current loop is cut off, but the data acquisition is not stopped |
4 | Circulation | Carry out the cycle test of the work step according to the actual requirements, which can be nested in multiple layers |
5 | Stop | The channel is completely stopped, and the battery circuit is completely disconnected from the equipment |
NO | Item | Parameter | ||
1 | Channel Nos. | 1-12 | ||
2 | Channel action mode | complete independence | ||
3 | Main channel working mode |
Charging: CCCV with constant current and voltage; Discharge: constant current discharge CD, constant power discharge CP; Stand still and stop. |
||
Abort condition of main channel test | Time, voltage, current, capacity, etc. | |||
4 | Main channel voltage |
Charging voltage range | 5V~100V | |
Discharge voltage range | 5V~100V | |||
Accuracy | ±(0.1%RD+0.1%FS) | |||
resolving | 1mV | |||
Main channel current |
Maximum output current | 20A, | ||
Minimum output current | 100mA | |||
accuracy | ±(0.1%RD+0.1%FS) | |||
resolving power | 1mA | |||
Parallel connection | Supporting parallel connection | 2channel | ||
Power | output power | Single channel continuous operation maximum power:2000W | ||
Auxiliary channel parameter cut-off function | When the auxiliary channel signal reaches certain conditions, the main channel step can be set to stop or convert. | |||
5 | control program |
1. Support power failure data protection, power failure, manual stop, and connection test from data file |
||
Safety protection conditions can be set, including: lower limit of voltage, upper limit of voltage, lower limit of current, upper limit of current, voltage and current trend. | ||||
The auxiliary channel protection conditions can be set. The parameters that can be set include: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit. | ||||
Number of cycles | Max:9999 | |||
Work step time unit | Support:h,min,s | |||
Data upload interval | Min:5S | |||
6 | Data display mode |
Loop List | There are cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, average charge/discharge voltage, etc. | |
Process List | There are process serial number, working mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. | |||
Detailed list | The serial number, system time, cumulative time, voltage, current, energy, power, etc. shall be recorded. | |||
7 | Data export mode |
The data can be converted into EXCEL and chart files, which can provide multiple data analysis curves such as charge discharge efficiency, charge discharge curve, voltage, capacity, current time characteristics, and can be imported into EXCEL. | ||
8 | Curve type |
X coordinate: total time, charge discharge capacity, cycle times, etc. can be set freely. | ||
Y coordinate: total voltage, current, capacity, individual temperature, charge discharge capacity, individual voltage, etc. can be set freely. | ||||
9 | software protection |
Power failure data protection, task suspension and recovery, overvoltage and over discharge protection, overcurrent and under current protection, capacity protection, over temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, and abnormal discharge voltage drop rate protection. | ||
Hardware protection | Battery reverse connection, over-current protection, over-voltage protection. | |||
Alarm function | The hardware has the functions of emergency cut-off switch, automatic shutdown after power failure, automatic load connection and disconnection, etc. | |||
10 | Output line | Four wire connection mode, current line and voltage line are separated. | ||
11 | Connection mode of test channel and battery pack | Alligator clip connection, alligator clip over-current greater than 30A, all channels are connected to alligator clip one-to-one | ||
12 | Software upgrade service | Upgrade software for free until the hardware configuration is incompatible | ||
13 | Battery pack test rack | |||
14 | Equipment test environment and technical requirements | Working mode: continuous Working environment: temperature - 10 ºC~ 45 ºC/humidity: 10% ~ 90% |