Customization: | Available |
---|---|
Additional Capabilities: | Pore Size Analyzing |
Application: | Pore Size Analyzing |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
|
3H-2000PS1 | 3H-2000PS2 | 3H-2000PS4 | 3H-2000PM1 | 3H-2000PM2 |
Degas Stations | 2 | 2 | 4 | 2 | 2 |
Analysis Stations | 1 | 2 | 4 | 1 | 2 |
P0 Test | √ | √ | √ | √ | √ |
BET | √ | √ | √ | √ | √ |
Total volume | √ | √ | √ | √ | √ |
Mesopore(p/p0>10-4) | √ | √ | √ | √ | √ |
Micropore(p/p0<10-4) | --- | --- | --- | √ | √ |
Isothe | √ | √ | √ | √ | √ |
Vacuum Pump | √ | √ | √ | √ | √ |
Turbo Vacuum Pump | --- | --- | --- | √ | √ |
1000 torr Transducers | √ | √ | √ | √ | √ |
10 torr Transducers | --- | --- | --- | Optional | Optional |
1 torr Transducers | Optional | Optional | √ | √ | |
0.1 torr Transducers | --- | --- | --- | Optional | Optional |
Degas Cold Trap | --- | --- | --- | √ | √ |
Analysis Cold Trap | --- | --- | --- | √ | √ |
Non Barrier Anti Flying and Anti Pollution Device | |
TMAX | Other company's Device |
Working process: if a very light sample is pumped under high vacuum, the sample will first fall into the dust filter bag through inertia, and a small part will fall into the anti pollution bottle through the dust filter bag without entering the air system. Compared with the barrier type, it will not affect the vacuum degree, but also protect the air system and completely avoid it The situation that the air tightness of the system decreases after the volatiles contaminate the valve pipeline | Working principle: in the process of degassing pretreatment, if a lighter sample is encountered, in the case of high vacuum, the sample will occur uplift boiling phenomenon. The conventional anti pollution is to protect the gas system by blocking, and the disadvantages of this blocking anti pollution device are as follows: |
Advantages of the non barrier anti pollution device: compared with the barrier anti pollution device, the non barrier anti pollution device can completely eliminate the evaporation boiling phenomenon of volatile samples in high vacuum, so as to avoid the air tightness drop of the system after the volatile pollutants pollute the valve pipeline. Patent technology: (1) static method specific surface and aperture analyzer with dust removal and pollution prevention device, patent No.: zl201320045881. X; (2) static method physical adsorption instrument with degassing level dust filter bag device, patent No.: zl201620714986.3. | 1. If it is effective for particles less than 2um, the filter element (filter cotton) needs to be increased, and if the filter element (filter cotton) is too much, the air extraction speed will be seriously affected, and the high vacuum degree cannot be obtained; 2. If the filter element (filter cotton) is too small, the particles with particle size less than 2um are basically ineffective, the samples will generate the phenomenon of uplift (pumping) and occur uplift (pumping) of samples It will enter the pipeline system, pollution valve and other air system, affecting the vacuum degree, causing cross contamination of the sample, high maintenance rate of the instrument, and affecting the service life of the instrument. |