TMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable Detector

Product Details
Customization: Available
Application: Pore Size Analyzing
Application Area: Chemical
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Overseas Services
The supplier provides overseas services and supports countries including Egypt, Belarus, Russia, South Korea, Thailand, Turkey, Singapore, Iran, India, Chile.

Overseas service content includes N/A, Debugging, Maintain, Repair, Training, Equipment Installation.
to see all verified strength labels (23)
  • TMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable Detector
  • TMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable Detector
Find Similar Products

Basic Info.

Model NO.
TMAX-3H-2000BET-A
Condition
New
Mixing Drum Shape
No
Stirring Type
Forced
Working
High Speed Mixer
Mixer Type
Planetary Mixer
Layout Type
Verticle
Operating type
Continuous Operating
Transport Package
Wood Packing
Specification
Customized
Trademark
Tmax
Origin
China

Product Description

TMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable Detector
3 Analysis Stations  Surface Area Porosity Analyzer with Ultra-stable Detector

3H-2000BET-A provides standard sample reference method, single-point and multipoint BET surface area measurements with speed, accuracy, and reliability. Samples having surface areas from 0.01 m2/g to over 1,000 m2/g are easily accommodated.  
TMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable Detector

The 3H-2000A/BET-A -High Efficiency Surface Area Analyzer
3H-2000BET-A measures surface area using the flowing gas method, which involves the continuous flow of an adsorptive and inert gas mixture over the sample at atmospheric pressure.
 
The 3H-2000BET-A's reproducibility is better than 1.5%. The 3H-2000BET-A features a built-in Dewar elevator for completely automated analysis and rewarming fan for rapidly warming the sample tube to increase the speed of the sample analysis.
 
Single injection calibration provides fast start-up and high sample throughput. Specially designed sample holders can be attached and removed from the instrument with one hand. These quick connect/disconnects have a built-in isolation valve to prevent sample contamination.
 
The 3H-2000BET-A features a Dewar support latch system that provides one-handed convenience and safe-guards against LN2 spills. Simple in design, the 3H-2000BET-A requires minimal training time and leaves little chance of operator error. Automatic mode switching for adsorption and desorption is accomplished without operator attention. The low purchase price of the 3H-2000BET-A and its accessories make this instrument one of the most inexpensive ways for a laboratory to begin measuring BET surface area.
 
Features
1. Ultra-stable detector eliminates drift and need for constant readjustment.
2. Cold trap conveniently Recessed at the side of the instrument. This placement reduces the chance of breakage .
3.Single-injection calibration requires only one control setting. Adaptable to any non corrosive adsorbate mix.
4. All controls and displays are at eye/arm level, out of spill zone.
5. Built-in sample preparation.
6.  The 3H-2000BET-A features a built-in dewar elevator for completely automated analysis and rewarming fan for rapidly warming the sample tube to increase the speed of sample analysis
7. The thermal conductivity detector eliminates temperature-induced drift resulting in highly repeatable results.
8. Single-injection calibration provides fast start-up and high sample throughput.
9. The 3H-2000BET-A features a dewar support latch system that provides one-hand convenience and safeguards against liquid nitrogen spills.
 
Selection Guide
     
 
3H-2000A 3H-2000BET-A
Degas Stations 4 4
Degas Method Flow Gas Flow Gas
Analysis Stations 3 3/4
Standard Sample Reference Method  (3 test results in 30min)  (3 test results in 30min)
BET ---  (4 test results in 150min)
Gas Mixed gas(20% Nitrogen,80%Helium) Two bottle of pure gas(Nitrogen and Helium)
Total volume --- ---
Pore Size --- ---
Vacuum Pump --- ---
Cold Trap

Test Reports

TMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable Detector
TMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable Detector
TMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable Detector



TMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable DetectorTMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable DetectorTMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable DetectorTMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable DetectorTMAXCN Brand 3 Analysis Stations Surface Area Porosity Analyzer with Ultra-Stable Detector

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier