Customization: | Available |
---|---|
Power Supply: | 220V/110V |
Certification: | CE, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Project index | Parameter index | |
Input Power | AC 220V ±10% / 50Hz | |
resolution | AD:16bit;DA:16bit | |
Input Resistance | ≥1MΩ | |
Input Power | 224W | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | Charge:10mV~5V;Discharge:2.5V~5V |
Accuracy | ± 0.05% of FS | |
Stability | 0.05% of FS | |
Current | Per Channel Current Range | 6mA~3A |
Accuracy | ± 0.05% of FS | |
Stability | 0.05% of FS | |
Time | Current Response Time | The Current gets to 6A Hardware Response Time is 1ms |
Step Time Range | 0.1s≤Single Step Time Range≤365*24 h, Time Form Support 00:00:00(h,min,s) |
|
Data Recording | Record Condition | Time△t:100ms |
Voltage△U:10mV | ||
Current△I:Range 1: 0.2mA Range2: 12mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | Constant Current Charge,Constant Voltage Charge, CC-CV Charge ,CP-Charge |
End Condition | Voltage,Current,Relative Time,Capacity,-△V | |
Discharge | Discharge Mode | Constant Current Discharge CP-D CR-D |
End Condition | Current,Current,Relative Time,Capacity,-△V | |
Pulse Model | Charge | Constant Current,Constant Power |
Discharge | Constant Current,Constant Power | |
Min Pulse Width | 500ms | |
Pulse Number | Single Pulse Step Support 32 different Pulse | |
Charge r To Discharge | One Pulse Step Can Support Continuous Charge And Discharge Change | |
Stop Condition | Voltage, Relative Time | |
DCIR Testing | Support Custom Access Point And Count The DCR | |
Cycle | Loop Measure Range | 1~65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function,Max Support 3 Layers | |
Protection | Software Protection |
|
|
||
Voltage and Current Testing Sample | 4-wire connecting | |
Noise | <85dB | |
Data Management | MySQL Database | |
Communication Means | TCP/IP Protocol | |
Data Output | EXCEL,TXT | |
Communication Interface | Ethernet Port | |
Main Channels | 8 |
Project index | Parameter index |
Working Temperature Range | 0ºC~40ºC |
Storage Temperature Range | -10ºC~45ºC |
Working Environment Relative Humidity Range | 30% ~ 80% RH |
Storage Environment Relative Humidity Range | 30% ~ 90% RH |