25ºC~150ºC 80L~1000L Humidity And Temperature Chamber
Model Available
Model |
TMAX-80(A~F) |
TMAX-150(A~F) |
TMAX-225(A~F) |
TMAX-408(A~F) |
TMAX-800(A~F) |
TMAX-1000(A~F) |
Internal Dimension |
400x500x400 |
500x600x500 |
600x750x500 |
600x850x800 |
1000x1000x800 |
1000x1000x1000 |
Internal Dimension WxHxD (mm) |
950x1650x950 |
1050x1750x1050 |
1200x1900x1150 |
1200x1950x1350 |
1600x2000x1450 |
1600x2100x1450 |
TemperatureRange |
Low Temperature(A:25°C B:0°C C:-20°C D:-40°C E:-60°C F:-70°C) |
|||||
HumidityRange |
20%~98%R.H.(10%-98% R.H. / 5%-98% R.H ,is a special optional condition, need Dehumidifier) |
|||||
Analytic Accuracy/ |
0.1°C; 0.1% R.H/±2.0°C; ±3.0% R.H. |
A.Testing Parameter
Temperature range |
25ºC~+150 ºC(Air-cooled type) Can be customized to below 0ºC |
Humidity range |
20%-98% RH (the distribution range is as follows)
|
The cooling rate (no-load) |
About 1ºC/min |
The heating rate (no load) |
About 3ºC/min |
Temperature stability |
±0.5ºC |
Analytical accuracy of temperature |
0.01ºC |
Precision of humidity control |
±2%R.H |
Temperature uniformity |
±2.0ºC |
Humidity uniformity |
≤±3%R.H(+2,-3%RH) |
Working noise |
A sound level is less than 75 dB (A) (measured in a soundproof room with 25 C ambient temperature and less echo; measured the average value of 8 points by A weighting; measured the level of each test point is 1 metre from the noise source and the height is 1 metre from the ground). |
Material of inner and outer boxes |
SUS # 304 |
Outer box light source |
High brightness lamp |
Structural design of stratosphere |
Effective avoidance of condensation at the top of the box |
Observation Window |
Observation sample use (W*L 28*35 cm) |
Anti-sweat design of windows |
Electrical heating device to prevent condensation of water and gas (40 W) |
Test Holes
|
Can be used for connect external test power cord and signal (diameter 50 mm) |
Machine pulley |
Pulleys are movable and positioned with strong bolts (200Kg/wheel) |
Insulation Layer |
Rigid polyurethane foam (its advantages are: 1. High efficiency and energy saving, seamless after filling, strong bonding after curing. 2. Seismic and compressive resistance, no cracking, no decay, no falling off after solidification. 3. It has ultra-low temperature heat conductivity, weather resistance and heat preservation. 4. High efficiency insulation, sound insulation, waterproof and moisture-proof after curing. 5. waterproof performance is good, because the foam hole is closed, the sealing rate is 95%, and the rainwater will not permeate through the hole. |
Inner rack |
Movable adjustable grids and two stainless steel strip grids (5.0 cm per grille) |
Box door |
Double-channel heat insulation and tight gas to effectively isolate external temperature leakage |
Leakage/Surge Protection |
FUSE. RC electronic surge protection for leakage circuit breakers |
Internal self-automatic detection and protection device of controller |
1. Data transmission detection between microcomputers 2. Temperature/Humidity Sensor→ circuit break or short circuit (+/- OVER) 3. Layer 1 high/low temperature over-temperature protection → Settings for operation control high and low temperature over-temperature protection |
Fault Detection and Control Interface(Automatic Detection and Protection Device for External Faults) |
1. High Temperature Overtemperature Protection of the Second Layer→Electronic high temperature overtemperature protection device 2. Layer 3 High Temperature Overtemperature Protection→High temperature overtemperature protection device 3. Protection of water-cut incineration→Humidity water cut-off protection and electric heat water cut-off air incineration protection 4. Compressor protection→Refrigerant pressure protection and overload protection. 5. Extended Protective Device→Reserve two sets of fault detection input expansion protection devices for use. |
Fault Abnormal Protection |
Cut off control power supply and fault reason indication and alarm output signal when abnormal fault occurs. |
Active Water Shortage Indicator |
Initiative prompt for lack of water on machine. |
Dynamic High and Low Temperature Protection |
Dynamic adjustment of high and low temperature protection value with setting conditions. |
Normal Temperature Protection |
After shutdown, the test area of the machine will be protected automatically by lowering to the normal temperature. |
Control Mode
|
1. The control system automatically adjusts the operation of the refrigerator according to the test conditions, so that the equipment is in the best energy-saving condition. 2. The refrigeration capacity of the evaporator is switched by the solenoid valve driven by the control system. 3. Compressor return air cooling circuit. |
Working Methods |
The first-order compression is adopted for the 0 ~40ºC model. Binary cascade refrigeration is adopted at 40 ~70ºC. |
Refrigeration Compressor |
The original imported French Taikang fully enclosed low noise rotor compressor. |
Refrigerant |
R404a/R23 (ozone depletion index is 0, R23 is used in cascade refrigeration system). |
Condenser |
Air-cooled: Finned tube heat exchanger. Water-cooled: shell-and-tube heat exchanger. |
Evaporator |
Finned tube heat exchanger (also used as dehumidifier). |
Plate heat exchanger |
Stainless steel brazed plate heat exchanger (cascade refrigeration system used). |
Throttling Device |
Expansion valve + capillary. |