Customization: | Available |
---|---|
Warranty: | 1 year |
Type: | Lithium Battery |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Equipment model | UPC60V40A-01NC |
Number of output channels of equipment model | 1CH (1 channel per device) |
Communication mode | RJ45(Network port) |
Charging voltage | DC 0 ~ 60V charging can be used to detect and set the voltage range, the maximum voltage is 60V |
Discharge voltage | DC 60 ~ 5V discharge can be used to detect and set the voltage range, the maximum voltage is 60V |
Charging current | DC 0.02~ 40A can be used to detect and set the current range, the maximum current is 40A |
Discharge current | DC 0.02~ 40A can be used to detect and set the current range, the maximum current is 40A |
Voltage accuracy | ±(0.05%RD + 0.05%FS) |
Current accuracy | ±(0.05%RD + 0.05%FS) |
Voltage resolution | 1mV The minimum unit used by a device to detect or set voltage |
Voltage stability | ≤0.05% |
Current resolution | 1mA The minimum unit used by a device to detect or set current |
Current stability | ≤0.05% |
Power output range | 0.5~Pmax = Vmax * Imax |
Input impedance | >=10 MΩ |
Input power | AC 220 V ± 10% / 50 Hz (cabinet power supply mode: three phase five wire) |
Power accuracy | ±(0.05%RD + 0.05%FS) |
Current response time | When the current output is 40A, the hardware response time is as follows:≤50ms |
Time setting range | Any setting within 0-9999 minutes, the time units are h, min and s, and the resolution is 0.1s |
Time accuracy | ≤±0.1% |
Recording method | Charging recording time, discharging recording time, static recording time and global recording time |
Recording frequency | 100mS~65535S |
Sampling frequency | About 10ms per box |
Charging mode | Constant current and voltage limiting, constant current and constant voltage, constant power charging, constant flow charging test (battery with protection board) |
Charging cut-off conditions | Voltage, current, time, capacity, temperature |
Discharge mode | Constant current and constant power discharge (battery with protection board) |
Discharge cut-off conditions | Voltage, current, time, capacity, temperature |
Protection function | Data abnormal recovery; battery reverse connection protection function; Software over-voltage, under voltage, over-current, under current and over capacity protection. The range of voltage and current protection value can be set, and prompt and record after protection; |
Number of single cycle work steps | ≤100 steps, with nested loop function |
Continuous working hours | The power of the equipment shall meet the requirements of full load and 365 * 24-hour uninterrupted operation of all channels |
Equipment noise | Less than 60dB |
Circuit structure | Modular structure design, easy to replace and maintain |
VCELL,TCELL | Auxiliary temperature and voltage can be selected and 16 channels in single box can be selected |
Software |
The software supports various kinds of connection, such as manual suspension connection, software shutdown connection, power interruption connection, equipment communication interruption connection and abnormal stop connection; It supports barcode scanning, and can scan one-dimensional code and two-dimensional code. There are scanning methods such as sequential scanning, channel skipping scanning, loading and disk scanning; Local test detailed data storage, you can view the current test data and historical data of each channel at any time. There are two ways to display the corresponding data and curve. It also supports the export of excel report in single or batch form. In addition, it can set the automatic data export after the test according to the needs. It supports capacity sorting and can grade sort the battery; The pass / ng results can be judged according to the specified cycle capacity, voltage and time; Support all kinds of work step protection and global voltage, current and temperature abnormal protection, and carry out abnormal alarm, support battery pack overcharge and over discharge protection test; Support channel parallel connection (optional according to equipment); Support unit conversion; Support database server background storage or MES docking; Software offline protection; The software provides free upgrades. |
Operating / storage temperature | 0ºC~40ºC/-10ºC~50ºC |
Relative humidity of working / storage environment | ≤70% RH / ≤ 80% RH (no condensation) |
Equipment maintenance | Non professionals are not allowed to open the case. Check the equipment joint regularly to prevent poor contact. |