Model | DSP1100-HP-I | DSP1100-HP-II |
Power | 3.5 KW | 3.5 KW |
Tube Size | Nickel base alloy steel Tube: 50mm O.D x 30mm I.D x 1000mm L | Nickel base alloy steel Tube: 85mm O.D x 50mm I.D x 1000mm L |
Product Dimensions (mm) | 580x370x515 | 580x420x565 |
Voltage | AC 208-240V Single Phase, 50/60 Hz | |
Temperature range | 100~1000° C (Continuous); 1100 C (<1 hour) | |
Max. Heating Rate | <= 20° C /min | |
Heating Zone length | 1. Two zones: each zone length 8" (200 mm) 2. Total 16" (400 mm) heating zone |
|
Constant Temp. Zone | 1. 150mm (+/-1°C) for each heating zone 2. A longer constant temperature zone ( about 250mm ) can be created by setting both zones at the same temperature |
|
Temperature Controllers | 1. 2 certified digital controllers with 30 programmable segments for precise control of heating rate, cooling rate and dwell time. 2. Built in PID Auto-Tune function with overheating & broken thermocouple protection. 3. Over temperature protection and alarm allows for operation without attendant(s). 4. +/- 1 ºC temperature accuracy. 5. Two K-type thermocouples (one for each zone). 6. RS485 Communications Port. |
|
Thermal Couples | K type | |
Temperature Accuracy | +/- 1° C | |
Heating Element | Fe-Cr-Al Alloy doped by Mo | |
Vacuum Flange & Fitting Ports | 1. One pair of SS 304 vacuum flange with double high-temperature silicone O-rings are Included 2. One Vacuum pressure gauge is installed, one digital vacuum gauge is available upon request at extra cost 3. The flange set has two 1/4'' Bard fittings, two needle valve, one set of KF25 quick clamp, one blank flange fitting, 1/4'' tube feedthrough port (for 1/4" O.D thermocouple insert) and a KF25 vacuum port. 4. Vacuum level can reach 10^-2 torr by quality mechanical vacuum pump and 10^-5 torr by molecular pump |
|
Application Notes | 1. Tube furnaces with quartz tubes are designed for using under vacuum and low pressure < 0.2 bars / 3 psi / 0.02 MPa.Vacuum pressure may only be safely used up to 1000°C. The flow rate for gasses should be limited to < 200 SCCM (or 200 ml/min) for reducing thermal shocks to the tube. 2. Attention: A two-stage pressure regulator must be installed on a gas cylinder to limit the pressure to below 3 PSI for safe operation. |
|
Warranty | One year limited warranty with lifetime support. | |