5V6A 512 Channel Battery Formation and Grading Machine Battery Capacity Charging and Discharge Tester

 

I. Overall description of equipment
The product model is mainly for cylindrical battery, which is compatible with (46200) to meet the switching production. After determining the new model number, replace the professional supporting fixture. This agreement includes the main processes such as formation and volume separation.

1.Chemical forming cabinet and volume dividing cabinet.
The open rack design is adopted. The power board is installed inside the equipment.
 The batteries are placed on the front and back sides of the equipment. The special cylindrical battery tray fixture is configured. Other types of replacement fixtures need to be charged separately. (the battery cells are shipped in material boxes and loaded and unloaded manually.);

Control mode: after placing the single row of batteries (16 batteries) in OK position, close the push rod to realize the simultaneous compression of the single row of probes. After the formation and volume separation, open the push rod, release the single row of probes at the same time, and manually remove the batteries.


II.Main configuration description
1.Equipment power supply
The power supply is composed of bidirectional converter, charge discharge control board and monitoring gateway board. The power supply, the formation cabinet and the volume dividing cabinet adopt an integrated structure; Built in DC bus for automatic energy regulation; Can bus is used for communication to realize the control and data management of each module in the background; It has an independent RJ45 data acquisition network interface, supports network communication and data interaction, and supports MES software to read and write system data.


2.Monitoring Software
The generalized monitoring software btsrealer and the data analysis software btsanalyzer realize the equipment monitoring function and the test data analysis function respectively. The software has the advantages of convenient installation, simple operation and high reliability. The main functions provided by the software are as follows. Please refer to the equipment operation manual for detailed operation methods.
1) Three levels of management authority are provided: administrator, engineer and operator, so as to facilitate different access to the equipment.
2) Provide process editing function: it can set the process flow (constant current, constant voltage, constant current, constant voltage, constant power, constant resistance, static, cycle), parameter settings (charge discharge current, voltage, static time, jump position, cycle times, etc.), limit conditions (time, capacity, Watt hour, current, voltage).
3) Display and control of real-time data: the software displays the cycle, work step, status, current, voltage, work step time, battery temperature, ampere hour, watt hour, file location and other information of each channel in a list manner. It can also jump, pause / continue, continue, stop, open data files, query process information and other operations for each channel.
4) Incoming call recovery function: in case of power failure in the plant area, the equipment can be automatically saved and stopped at the current work step. After the incoming call, it can be continued from the breakpoint.
5) Data file name management: you can customize the data file name of each channel and specify the path to save the file.
6) Data file import function: by importing data files from other computers or channels, the tested battery can be flexibly transferred to other devices.
7) Data file export function: process files, curve graphs, work step summary data, detailed record data, etc. can be exported to excel with trade-offs according to requirements, so as to avoid repeated processing of a large number of useless data.
8) Graphic display function: it can display the voltage time, current time and capacity voltage curves of a specific cycle or all cycles, and provide the functions of printing, copying and scaling graphics.
9) Data file collapse / expansion function: the data file can be folded / expanded at three levels to quickly browse the test data. At the same time, the charging and discharging data of each cycle are summarized and the efficiency is calculated.
10) Remote monitoring: through the internal LAN of the enterprise, the configured equipment can be remotely monitored.
11) Log management: through the system log management, the working status and fault information of the system can be recorded in real time to track the use problems and fault codes of the equipment and facilitate the analysis of problems.
12) It has barcode input function and status indicator.
13) It has the real-time monitoring function of charging and discharging voltage and current curve and the prompt of fault information (protection of fluctuation points) after the protection stops.
14) With battery reverse connection protection. When the positive and negative poles of the battery are reversed, the system will automatically force the battery to sleep and prompt in the software interface; At the same time, the equipment itself shall not be damaged in case of reverse connection.
15) Data recording conditions can be set as voltage change (≥ 1mV), current change (≥ 1mA) and time interval (≥ 1s).
16) When deleting a step file, you can manually select whether to delete the corresponding data file at the same time.
17) Sorting function: the battery can be classified according to the charging and discharging capacity and platform voltage at different stages.

3.Battery tray code scanning
The code scanning of battery tray mainly realizes a code scanning function, which records the barcode in the channel, saves it in the form of a file, locally stores or uploads it to the MES system, and completes the code scanning of the whole tray.
Key introduction:
Load: loads an existing barcode information file.
New: create a new pallet code scanning, clear the pallet barcode and start scanning.
Save: save the scanned battery barcode by platform.
Clear: clear the battery barcode of the tray.
Continue: when the focus leaves the code scanning interface and pauses, click continue scanning to continue scanning.
Off: turn off battery code scanning, and no code scanning is allowed.
General use: new, scan, save and close.
Note: when code scanning is paused, code scanning cannot be continued. Click the [continue] button to continue code scanning.

4.Main technical indicators
Item Parameter
Voltage voltage test range constant current 0~5000mV
  resolving power 1mV
  accuracy ±(0.05%F.S+0.05%R.D)
Current electric current constant current 20~6000mA
  resolving power 1mA
  accuracy ±(0.1%F.S+0.1%R.D)
Time Single step setting range 65535 seconds
  resolving power 1seconds
  data record ≥1S,support ΔT(≥1S),ΔI(≥1mA),ΔV(≥1mV)
  Accuracy correction period 6 months
Operating mode control model Single channel independent control
  charge Constant current charging CC, constant voltage charging CV, constant current constant voltage CCCV
  discharge Constant current discharge CD
  work step switching conditions Current, voltage, capacity, time
Energy consumption Charging efficiency 70%(highest)
  Feedback efficiency 65%(highest)
Protection function Voltage protection Undervoltage and overvoltage protection
    Upper and lower voltage limit warning voltage, forced voltage protection
    Voltage and current fluctuation rate protection (abnormal trend)
  Safeguard Battery temperature protection (optional): detection range: -25 °~ 110 °, accuracy ± 2 °
    Battery anti reverse protection: battery reverse connection does not work and the equipment is not damaged
    Battery line drop protection: it can identify abnormal power line and detection line
  Power down connection After abnormal power failure or failure of the equipment, the test can be resumed at the original test position and the data continuity can be ensured
other signal communication TCP/IP protocol
  appearance Computer grey (if there are special requirements, the color board shall be provided when the contract is signed)
  distribution AC380V ± 10%, three-phase five wire system, upper incoming line
  Environmental requirements Ambient temperature: 0-45 ºC
 

TMAXCN Brand 5V6a 512 Channel Battery Formation and Grading Machine Battery Capacity Charging and Discharge Tester


TMAXCN Brand 5V6a 512 Channel Battery Formation and Grading Machine Battery Capacity Charging and Discharge Tester 
 



TMAXCN Brand 5V6a 512 Channel Battery Formation and Grading Machine Battery Capacity Charging and Discharge TesterTMAXCN Brand 5V6a 512 Channel Battery Formation and Grading Machine Battery Capacity Charging and Discharge TesterTMAXCN Brand 5V6a 512 Channel Battery Formation and Grading Machine Battery Capacity Charging and Discharge TesterTMAXCN Brand 5V6a 512 Channel Battery Formation and Grading Machine Battery Capacity Charging and Discharge TesterTMAXCN Brand 5V6a 512 Channel Battery Formation and Grading Machine Battery Capacity Charging and Discharge Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory
Plant Area
>2000 square meters
Management System Certification
ISO 9001