Items |
Values |
Input AC |
AC 220V/110V ±10% / 50Hz |
Input power |
851 W |
Resolution |
AD:16bit;DA:16bit |
Input impendence |
≥1MΩ |
|
CV output range |
25mV~5V |
|
Min discharge voltage |
1.0V for universial holder,1.5V for 2m cable |
Voltage |
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
|
Output range/channel |
Range1: 5mA-1A; Range2: 1A-12A |
|
Accuracy |
± 0.05% of FS |
Current |
CV cut-off current |
Range1: 2mA; Range2: 24mA |
|
Stability |
± 0.05% of FS |
|
Output power/channel |
60 |
W |
Power |
Stability |
± 0.1% of FS |
|
Current rsponse time |
Max rising time:1ms |
Time |
Working step time |
≤(365*24)h/step Time format-00:00:00.000(h,m,s,ms) |
|
|
Min data record interval:100ms |
|
Data record conditions |
Min voltage change:10mV |
Data record |
|
Min current change:Range1: 2mA; Range2: 24mA |
|
Frequency |
10Hz |
|
Charge modes |
CC,CV,CCCV,CP |
Charge |
Cut-off condition |
Voltage,Current,Time,Capacity,-△V |
|
Discharge modes |
CC,CP,CR,CV |
Discharge |
Cut-off condition |
Voltage,Current,Time,Capacity,-△V |
|
Charge |
CC,CP |
|
Discharge |
CC,CP |
|
Min pulse width |
500ms |
Pulse |
Pulse counts |
Up to 32 |
|
Chg and Dischg switch |
Supported |
|
Cut-off condition |
Voltage,Time |
DCIR |
Supported |
|
Max cycles |
65535 |
Cycle |
Max steps |
254 |
|
Cycle nest |
3 |
|
|
Power-off data protection |
|
|
Off-line operation mode |
Protection |
Safety protection |
User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc. |
Channels feature |
Independent pairs of closed loop for constant |
Channels control mode |
Independent control |
Data acquisition method |
Kelvin connection |
Noise |
<85dB |
Database |
MySQL |
Communicatin |
TCP/IP |
Operating system |
Windows 7/8/10 64 bit |
Data export |
EXCEL,TXT,CSV,PDF,Plot/Graph |
Disk drive |
500GB |
Communication port |
Ethernet port |
Leak Current |
0.0000005mA |
Channels per unit |
8 |
Operation and storage environment requirement |
Items |
Values |
|
0ºC~40ºC (When the temperature is 25±10ºC, the accuracy error caused by temperature change is less than 50ppm /ºC) |
Operation environment temperature |
Storage environment temperature |
-10ºC~50ºC |
Operation environment humidity |
≤70% RH(no moisture condensation) |
Storage environment humidity |
≤80% RH(no moisture condensation) |
Clamps and dimensions |
Items |
Values |
|
|
|
|
|
|
Tester pictures |
|
|
|
|
|
|
Clamps pictures |
Alligator |
Polymer |
Coin |
|
Pictures just for reference |
Dimensions(W*D*H)(mm) |
3U3F,480*730*130 |