Customization: | Available |
---|---|
Warranty: | 1 Year |
Type: | Lithium Battery |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1,Model | ||
2,Channels information | ||
1. Channels quantity | Channels quantity in one unit | BTS-6000 Specification6 |
2. Main channel | Channel feature | Constant current source and constant voltage source dual closed loop control |
Channel control mode | Independent control | |
Channel parallel connection | Support max 4 channels parallel mode. Pulse and SIM tests will be disabled in channels parallel mode. |
|
3,Power grid side parameters | ||
1.Input power | AC380V±15% 50/60±5Hz | |
2.Power factor | ≥99%(Full load) | |
3.THDi | ≤5%(Full load) | |
4.Input resistance | ≥1MΩ | |
5.Input power | 70.6KW | |
6.Input current | 107.3A/single | |
7.Overall system efficiency(Max) | 90% | |
8.Noise | ≤65dB | |
9.Voltage and current sampling | Four-wire connection(same port for charging and discharging) | |
10.Power control module type | MOSFET | |
11.Input power wiring method | Three-phase-five wire system | |
12.Power input protection | Anti-surge, anti-silos, anti over or under frequency, anti over or under voltage, anti phase absence, etc. | |
4,Functions and performances | ||
1. Voltage | Output range | Charge:0V~100V |
Discharge:3V~100V | ||
Min discharge voltage | 3V | |
Accuracy | ±0.02% of FS | |
Resolution | 24bit | |
2. Current | Output range | 0.5A~100A |
Accuracy(independent range) | ±0.05% of FS | |
CV cut-off current | 100mA | |
Resolution | 24bit | |
3. Power | Single channel output power | 10KW |
Whole machine output power | 60KW | |
4. Time | Current response time | ≤3ms |
Current conversion time | ≤6ms | |
Min. step time | 0.1s | |
5. Charge/Discharge modes | Charge/Discharge modes | CCC, CVC, CC-CVC, CPC |
CCD, CVD, CPD, CRD | ||
Cut-off condition | Voltage, Current, ΔTime, Capacity, -ΔV | |
6. Simulation | Charge | Current, Power |
Discharge | Current, Power | |
Switch | Support continuous switching between charge and discharge | |
Cut-off condition | Time, step line | |
Steps file lines | 1,000,000 | |
7. Pulse Mode | Charge | Current ,power |
Discharge | Current, Power | |
Min pulse | 100ms | |
Pulse counts | Up to 32 | |
Charge and discharge switch | supported | |
Cut-off condition | Voltage, ΔTime | |
8. DCIR | DCIR by calculation | |
9. Safely protection | Software protection | Power off data protection |
Offline mode function | ||
Safety protection conditions can be set, including:voltage lower limit ,voltage upper limit ,current lower limit ,current upper limit ,delay time, etc. | ||
Hardware protection | Anti-reverse connection, over-voltage, over-current, over-temperature, etc. | |
5,Data management and analysis | ||
1. Step setting method | Form editing | |
2. Data report | Recording conditions | Minimum time interval: 10ms(connected with AUX channel:100ms) |
Minimum voltage interval: 0.2V | ||
Minimum current interval: 0.2A | ||
Recording frequency | 100Hz(connected with AUX channel:10Hz) | |
3. Database | MySQL database | |
4. Data output | Excel, Txt | |
5. Curve type | Templates available, customization supported | |
6. Bar code scanning | Support bar-code scanning function | |
Management and traceability of historical data | ||
6,Communication | ||
1. Host computer communication | TCP/IP protocol | |
2. Communication port | Ethernet | |
3. Communication baud rate of the testers | 1M | |
4. Host computer communication baud rate | 10M~100M adaptive | |
5. Communication setup | Set up a LAN(local area network) through switches and routers | |
6. Communication expansion(optional) | Support CAN, RS485 communication and BMS communication, with DBC configuration function | |
7,Environmental requirements, dimension and weight | ||
1. Operation environment temperature | -10ºC~40ºC(When the temperature is 25±10ºC, the accuracy error caused by temperature change is less than 0.005% of FS per degree) | |
2. Storage environment temperature | -20ºC~50ºC | |
3. Operation environment humidity | ≤70% RH(no moisture condensation) | |
4. Storage environment humidity | ≤80% RH(no moisture condensation) | |
5. Dimension W*D*H | 600*800*1800(mm) | |
6. Weight | about 275.2KG |