Input power | AC 220V ±10% / 50Hz | |
Volta ge |
Per Channel Voltage Range |
5-30V |
Accuracy | ±(0.2% of reading + 0.2% of range) | |
Curr ent |
Per Channel Current Range |
50~10000mA |
Accuracy | ±(0.2% of reading + 0.2% of range) | |
Discharge range | 50~20000mA | |
Accuracy | ±(0.2% of reading + 0.2% of range) | |
Charg ing |
CV cut-off current |
Minium: 50mA |
Capac ity |
Accuracy |
±1‰ |
Pow er |
Per Channel Output Power |
600W |
Time |
Current Response Time |
The Current gets to 20A Hardware Response Time is 2s |
Step Time Range | 0-999 hours/step | |
Data recording interval | 5S | |
Middle machine version | 1.1series | |
Char ge |
Charge Mode |
Constant Current Charge,Constant Voltage Charge, CC-CV Charge ,CP-Charge |
End Condition | Voltage,Current,Relative Time,Capacity, | |
Disch arge |
Discharge Mode |
Constant Current Discharge CP-D CR-D |
End Condition | Current,Current,Relative Time,Capacity, | |
Cycle |
Loop Measure Range |
1-999times |
Max Steps Per Loop | 100 | |
Voltage and Current Testing Sample |
4-wire connecting |
|
Data Management | MySQL Database | |
Communication Means | TCP/IP Protocol | |
Data Output | EXCEL,TXT | |
Communication Interface | Ethernet Port | |
Working Temperature Range | 0ºC~40ºC | |
Storage Temperature Range | -10ºC~50ºC | |
Working Environment Relative Humidity Range |
30% ~ 70% RH |
|
Storage Environment Relative Humidity Range |
30% ~ 70% RH |