TMAXCN Brand 10000m3/H NMP Solvent Recovery System for Positive Electrode Coating System

Product Details
Customization: Available
Production Scope: Product Line
Production continuity: Continuous
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Overseas Services
The supplier provides overseas services and supports countries including Egypt, Belarus, Russia, South Korea, Thailand, Turkey, Singapore, Iran, India, Chile.

Overseas service content includes N/A, Debugging, Maintain, Repair, Training, Equipment Installation.
to see all verified strength labels (23)
  • TMAXCN Brand 10000m3/H NMP Solvent Recovery System for Positive Electrode Coating System
  • TMAXCN Brand 10000m3/H NMP Solvent Recovery System for Positive Electrode Coating System
  • TMAXCN Brand 10000m3/H NMP Solvent Recovery System for Positive Electrode Coating System
  • TMAXCN Brand 10000m3/H NMP Solvent Recovery System for Positive Electrode Coating System
Find Similar Products

Basic Info.

Model NO.
TMAX-NMP-10000
Condition
New
Automation
Automatic
After-sales Service
1 year
Warranty
1 Year
Certification
CE, ISO
Transport Package
Wood Packing
Specification
Customized
Trademark
TMAX
Origin
China

Product Description

TMAXCN Brand 10000m3/H NMP Solvent Recovery System for Positive Electrode Coating System



10000m3/h NMP Solvent Recovery System for Positive Electrode Coating System 

 


I. Party A's project Content:
A positive electrode coating machine with a maximum exhaust capacity of 10,000 M3/H.
Party A requires: to configure a set of 10,000M3/H for the cathode coating machine3NMP recovery system, emission standard.
 
II. Party B's Plan:
A set of NMP recovery system, emission standards.
Configuration Listing:

device name quantity remarks
The NMP recovery system host A set 1. Recovery rate: 99%
2. Recovery concentration: 80%
3. Extail gas emission concentration: <50 mg / m3
4. Installed power is 9.95KW
spray tower One set (2 towers)
Cooling water tower A set
fluid reservoir One
 
III.Equipment Profile:
1. The maximum 10000M3At / h. In order to realize N-methyl pyrrolidenone (NMP) solvent recovery in cathode process exhaust, a new NMP recovery system is planned to achieve the purpose of energy saving and environmental protection.
2. The recovery system adopts the NMP recovery method of cooling circulating water and water absorption (spraying concentration + water washing gas), so as to maximize the requirements for the recovery of NMP gas discharged from the coating machine under the premise of economy and energy saving.


IV.Introduction of the system principles.technical feature:
1. Introduction of the system principles
It is used for the recovery of N-methyl pyrrolidenone (NMP) organic solvent discharged by the coating machine in the production process of lithium ion battery, under the condition of low energy consumption, makes the waste gas discharge to the standard, and realizes environmental protection, energy saving and raw material recovery.The NMP exhaust gas of the system is discharged to the atmosphere after cooling circulating water cooling + exhaust water washing. After treatment, the exhaust gas emission concentration is <50mg / m³, which meets the environmental protection requirements (see No.11 Non-methane total hydrocarbon, Table 5 of Battery Industry.
2. Technical characteristics of the equipment
A.It can start the applicator control system with one key, and automatically control the whole NMP recovery system. The equipment is equipped with monitoring operating conditions and abnormal alarm devices such as: (fan overload, phase absence leakage protection and abnormal alarm, etc., simple operation, safe and reliable).
B.The system controls safety and protection to meet the continuity requirements of safety production.
C.The system is equipped with frequency converter and applicator exhaust fan to ensure stable coating production.
D.Unique equipment selection, equipment manufacturing, equipment installation methods and optimized process flow, to eliminate the general NMP recovery system often appear run, risk, drop, leakage and other phenomena.
E.After the installation of the whole system, the commissioning personnel shall strictly follow the regulating specifications of the equipment, and will not affect the use of the equipment due to the differences in the technical level of the operating staff.
 
V.Equipment process:
1. Adopt the front cooling circulating water cooling condensation recovery and rear exhaust gas demist treatment process, low energy consumption, high efficiency, low operation and maintenance costs, and meet the environmental protection emission standards.During the coating process, NMP is heated and evaporated into gas. After entering the recovery system, the recovery system uses a pipe wing cooler to cool the NMP waste gas. After cooling, the waste gas is condensed into liquid, and the NMP condenses into foggy droplets more quickly into liquid recovery.Finally, the exhaust gas is concentrated again by the washing and pre-cooling device and discharged through the defogging system into the atmosphere.
2. Equipment recovery process: containing NMP waste gas after waste heat recovery device into the NMP recovery system, in the recovery system for tertiary water-gas heat exchange from about 120ºC to about 30ºC, there is a lot of NMP precipitation, NMP gas concentration gradually reduced, exhaust gas after induced fan booster line, gas and liquid full contact on the packing surface, condensation into liquid, waste liquid fell into the recovery box after the waste liquid pipe automatic drainage into the storage tank.Now over 90% of the exhaust gas has been recovered; the exhaust gas enters the spray system through two spray circulation water adsorption, and the NMP content in the exhaust gas is less than the specified emission value. The set concentration of the spray system circulates the exhaust gas after many cycles.
 
VI.technological guidance
1. Purification efficiency: (stable coating)
Tail gas emission concentration <50mg/m³
NMP percent recovery ≥99%
The NMP recovery concentration of the indicated ≥80%
 
VII.Recycle the system host configuration
order number Organization name Part name material quality specifications and models manufacturers
1 Host configuration heat exchanger aluminium pipe 900*900*500*2 QR self-control
2 Table cooler Copper pipe, aluminum wing 900*900*200*2 ASD
3 Table cooler Copper pipe, aluminum wing 900*900*200*2 ASD
4 Table cooler Copper pipe, aluminum wing 900*900*200*2 ASD
5 gas-liquid separator 304 Stainless steel 900*900*50*2 QR self-control
6 induced draft fan cast steel 3KW Odo.Xin wind
7 Host box 201 Stainless steel 1.5mm QR self-control
8 The frame column of the whole machine 201 Stainless steel 50*50*3 Hong and sincere / Dahua
9 The outer frame of the whole machine is sealed 201 Stainless steel 1.0mm Hong and sincere / Dahua
10 Water cooling circulation section Cooling water tower glass fiber reinforced plastics 30T Good far
11 circulating pipe PVC 6.0mm/1.6mpa Joint plastic
12 circulating water pump cast steel 2.2 kw Source
13 Scattered heat fan cast steel 0.75kw Good far
14 NMP waste liquid storage fluid reservoir 201 Stainless steel 900*2000 QR self-control
15 running piping Aluminum plastic pipe d20mm Zeke pipe industry
16 infusion pump magnetic drive pump 0.5 kw*2 /
 
VIII.Equipment size
name size Full load quality
The NMP recovery system host Approximately: long 2900 wide 1650 high 1750 1.2T
Cooling water tower 1895*1600 0.3T
spray tower H2200*φ1000 0.6T
fluid reservoir φ1000*2000 0.8T
 
 
IX. Control box configuration
Number name model quantity
1 air switch 4P/60A One
2 single pole switch 1P/10A Two
3 frequency transformer 3KW One
4 AC contactor 1210.2510 Five
5 thermal overload relay 4A/13A Four
6 pilot lamp Red, green Two
7 change-over switch NP2 Two
8 fuse 6A A set
9 Time broken electrical appliances 40n One
10 thermostat 18/H Two
11 alarm lamp A d16-22sm One
12 Control the electric box 300*200*150  600*500*200 Each 1

 
X.Process characteristics of the spray tower
1. All-stainless steel spray tower ensures the NMP exhaust emission standard, and can ensure the normal, stable and long-term operation of the spray tower.According to the successful experience of our company, the power cord of the spray tower and NMP recovery device is incorporated into the same control box, simple operation and management, easy to use, and prevent the failure to open the spray tower.
2. Improved the stability and safety of the recovery device and the cooling system.
3. Each set of recovery device and spray tower is linked with the coating machine. The applicator opens the recovery device and the spray tower by itself, which can ensure the safe production and smooth operation of the applicator and recovery device.
4. Emission standards can meet customer requirements.


TMAXCN Brand 10000m3/H NMP Solvent Recovery System for Positive Electrode Coating System
TMAXCN Brand 10000m3/H NMP Solvent Recovery System for Positive Electrode Coating SystemTMAXCN Brand 10000m3/H NMP Solvent Recovery System for Positive Electrode Coating SystemTMAXCN Brand 10000m3/H NMP Solvent Recovery System for Positive Electrode Coating SystemTMAXCN Brand 10000m3/H NMP Solvent Recovery System for Positive Electrode Coating SystemTMAXCN Brand 10000m3/H NMP Solvent Recovery System for Positive Electrode Coating System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier