Customization: | Available |
---|---|
Production Scope: | Product Line |
Condition: | New |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
120V 30A Regenerative Battery Pack Charge And Discharge Aging Machine
Indicator items | Indicator parameters | |
Equipment model | TG8000-120V30A | |
Number of single machine channels | AC 380V ±15% / 50Hz±2Hz | |
Maximum output power | 18KW | |
Charge discharge power factor | >0.99 (full load) | |
Total harmonic distortion rate of charging and discharging current | <5% (full load) | |
Overall efficiency | 85% MAX | |
Sampling resolution | AD:24bit | |
Input impedance | ≥1MΩ | |
Voltage | Output voltage range | Charging: 5V~120V, discharging: 5V~120V continuously adjustable |
Accuracy | ±0.1%FS | |
Sampling time (S) | <1S | |
Stability | ±0.1%FS | |
Current | Output current range | Charge and discharge: 100mA~30A continuously adjustable |
Accuracy | ±0.1%FS | |
Sampling time (S) | <1S | |
Stability | ±0.1%FS | |
Power | Accuracy | ±0.1%FS |
Time | Step time range | ≤ (365 * 24) hours/step time format supports 00:00:00 (H, min, S) |
Rise time of charging and discharging current (5%~95%) |
≤20ms | |
Charge discharge switching time | ≤40ms | |
Data record | Data recording conditions | time frame Δ t: (10ms-60000 s) |
Voltage Δ U:(7.4V ~ 120V) | ||
Current Δ I:(0.1 ~ 30A) | ||
Recording frequency | 50Hz | |
Charge | Charging mode | Constant current charging, constant voltage charging, constant current constant voltage charging |
Cut off conditions | Voltage, current, relative time, capacity, unit voltage, unit temperature | |
Discharge | Discharge mode | Constant current discharge |
Cut off conditions | Voltage, current, relative time, capacity, unit voltage, unit temperature | |
Loop | Cycle test range | 1~65535 times |
Number of work steps per cycle | 254 step | |
loop nesting | With nested loop function, supporting up to 3 layers of nesting | |
Protection | Security protection (global protection) | Power loss data protection |
The safety protection conditions can be set, and the setting parameters include: voltage upper limit, voltage lower limit, current upper limit, current lower limit, energy, monomer voltage, monomer temperature | ||
Equipment protection function | Transformer over temperature protection, output short circuit protection, power module over temperature protection, equipment over-voltage protection, equipment over-current protection, equipment battery reverse connection protection, emergency shutdown. | |
Equipment exhaust mode | Forward air and backward air | |
Whether the equipment has emergency stop function | Yes | |
Isolation mode | High frequency isolation | |
Cooling mode | Forced air cooling | |
Channel characteristics | The constant current source and constant voltage source adopt independent double closed loop structure | |
Channel control mode | Independent control | |
Voltage and current detection sampling | Four wire connection | |
Weight | <800kg | |
Degree of protection | IP20 | |
Noise | <75dB | |
Database | MySQL database is used for centralized management of test data, which can be uploaded to the client's background server | |
Communication mode of upper computer | Based on TCP/IP protocol | |
Data output mode | EXCEL, TXT, charts | |
Working temperature | -10ºC~40ºC |
4.Selection of battery pack charge and discharge aging machine: