Item |
Specification |
1.Electrolyte |
|
1 ,component |
organic matter |
2, Density |
1.0~1.5 g/cm3 |
2. Electrolyte |
|
1,Injection mode |
Vacuum injection of electric double-head pump |
2,Injection accuracy |
≤40g accuracy:±0.1g |
3,Infusion volume range |
10g-100g |
4,Precision of injection volume after sealing |
The accuracy of the weight after sealing and before injection can be less than (+0.2g). |
5,Diffusion°assing mode |
Secondary diffusion°assing, Maximum vacuum degree - 0.08 Mpa |
6,Diffusion°assing time |
Arbitrary setting of 1-99 seconds (Note: diffusion°assing time directly affects equipment efficiency) |
3.Sealing |
|
1,Sealing head width |
5 mm±0.1 mm (4-8mm changeable) |
2,Sealing head length |
170mm±0.2 mm |
3,Pressure |
0.1MPa~1MPa;Minimum adjustment accuracy is 0.1 MPa |
4,Time |
0.5s~99s;adjustable; |
5,Sealing head temperature |
room temperature~250ºC;adjustable;accuracy:±1ºC |
6,Sealing performance |
Flat surface, no wrinkles, no bubbles, no stripping between the aluminium-plastic film, good sealing performance |
7,Sealing head material |
NAK80 |
8,Temperature display |
Display temperature deviation from actual temperature ±1ºC |
9,Temperature uniformity of sealing head |
The range of temperature distribution is less than ±2ºC |
10,Temperature rise speed |
It takes less than 20 minutes to rise from 25ºC to 200ºC. |
5. Product |
|
1,First pass rate |
≥99% (Except for bad incoming materials, such as too short air bag to inject liquid, etc.) |
2, Malfunction Rate |
≤5% |
3,Equipment production efficiency |
Actual production≥16PPM(Calculate according to four acceptance types of cells on each set of fixtures) |
Dry run≥20PPM(Calculate according to four acceptance types of cells on each set of fixtures) |
4 ,Appearance |
Flatness, no wrinkles, no leakage, no drip, etc. |
5,Total weight of the whole machine |
About 3500 kg;Ratio of total weight to bearing area≤500kg/m2 |
6,Maximum size of equipment |
L*W*H:2500mm×1700mm×2450mm |
Water, electricity and gas requirements |
Power supply |
AC380V ±10% 50Hz/60Hz Power:6KW(self-prepared) |
Compressed air source |
≥0.6MPa 30L/S (Utilization ratio:50%) |
Drying gas source |
≥0.6MPa(User-provided drying system) |
Vacuum source |
≤-0.09MPa 40L/S (self-prepared) |
Ambient temperature |
20~50ºC;Relative humidity:0~90%RH(User-provided dehumidification system) |
Injection pump |
Two sets of electric injection pump(self-prepared) |